Message:

remove "no induced processes" so that these are the best possible sims. original meeting did not include UTA ionization which changes the temperature

Files:
1 modified

Legend:

Unmodified
Added
Removed
  • trunk/tsuite/auto/agn_lex00_um1.in

    r1168 r1957  
    11title low-ionization x-ray ionized cloud from Lexington 2000 
    22stop column density 16 
    3 no induced processes 
    43print lines column linear 
    54print lines sort intensity  
     
    5049c the asserts 
    5150// >>chng 06 aug 17, from 142100 to 152100, update Badnell dr  
    52 assert temperature hydrogen 2 152100 K 
     51// >>chng 08 aug 20, from 152100 to 1.628e5 remove no induced, include UTA 
     52assert temperature hydrogen 2 1.628e5 K 
    5353punch transmitted continuum "agn_lex00_um1.trn"  units keV  
    5454c 
    5555c agn_lex00_um1.in  
    5656 
     57This is one of the "warm absorber" simulations presented at the Lexington 
     582000 meeting on nebulae.  Pequignot et al. summarized in 2001ASPC..247..533P. 
     59It is necessary to also include the command 
     60no induced processes 
     61to obtain the results presented there.  This disables UTA ionization, 
     62a process that was not included in the calculations presented in the paper. 
    5763 